Biofinity Multifocal Contact Lens Fitting Guide
Biofinity® multifocal lenses offer a streamlined fitting process, informed by practitioner experiences. This guide simplifies lower ADD power fittings,
utilizing the D lens design for both eyes, while maintaining flexibility for higher ADD powers to achieve exceptional vision performance.
Biofinity® Multifocal contact lenses are designed to provide exceptional vision correction for presbyopia, offering a seamless transition between distance and near vision. These lenses utilize a unique aspheric design, creating a smooth progression of power across the lens surface. This innovative approach minimizes the visible transition zone, resulting in clear vision at all distances.
The fitting philosophy centers around simplifying the process for eye care professionals, leveraging real-world experiences to optimize outcomes. Biofinity Multifocal lenses are crafted from a silicone hydrogel material, promoting high oxygen permeability for enhanced comfort and eye health during extended wear. This guide will detail the steps for successful fitting, ensuring patient satisfaction.
Understanding Multifocal Lens Designs
Multifocal contact lenses correct presbyopia by incorporating multiple power zones into a single lens. These zones typically include a distance zone for clear far vision, an intermediate zone for computer use, and a near zone for reading. Biofinity® Multifocal employs a concentric design, featuring alternating rings of distance and near correction.
This design allows for a smooth transition between focal points, minimizing the need for the eyes to constantly refocus. Different designs, like D and N, cater to varying ADD power needs. Understanding these nuances is crucial for successful fitting, ensuring optimal visual acuity and patient comfort. Proper lens selection is key to addressing individual visual demands.
Key Features of Biofinity Multifocal
Biofinity® Multifocal lenses are crafted from comfilcon A material, offering high oxygen permeability for exceptional comfort and eye health. The lens features a balanced progressive addition design, providing a smooth transition between distance, intermediate, and near vision. This concentric design minimizes visual disturbances and enhances clarity.
Available in both D and N lens designs, Biofinity® Multifocal caters to a wide range of prescriptions and ADD powers. The lenses demonstrate quick equilibration, allowing patients to adapt rapidly. Their consistent wettability contributes to all-day comfort, making them an excellent choice for presbyopic patients seeking superior vision correction.

Initial Patient Assessment
Begin with a comprehensive refraction and verify eye dominance using the fogging technique to establish a solid foundation for successful Biofinity® Multifocal fitting.
Comprehensive Refraction
A new, thorough refraction is the crucial first step in the Biofinity® Multifocal fitting process. Correct the spherical equivalent for vertex distance to ensure accuracy. This establishes the baseline distance prescription. Prioritize maximizing plus power for distance vision, avoiding over-minus corrections. Accurate refraction minimizes potential issues later in the fitting process. Consider patient complaints and lifestyle needs during refraction. Document all findings meticulously. This detailed approach ensures the most appropriate starting point for multifocal lens selection and ultimately, optimal visual outcomes for the patient. Remember, a solid refraction is paramount for success.
Verification of Eye Dominance
Accurate eye dominance assessment is essential before selecting the Biofinity® Multifocal lens design. Utilize the fogging technique – a simple, reliable method to determine which eye leads for distance vision. This impacts ADD power distribution. The dominant eye typically receives the higher ADD power, while the non-dominant eye receives a lower power. Correctly identifying dominance ensures balanced binocular vision and minimizes adaptation challenges. Document the findings clearly. This step directly influences the initial lens selection, optimizing the potential for clear vision at all distances. Proper dominance verification is key to a successful fit.
Determining ADD Power Requirements
Precisely determining the appropriate ADD power is crucial for Biofinity® Multifocal success. Begin with a comprehensive refraction, correcting for vertex distance. Consider the patient’s visual demands – near and intermediate work distances. For an ADD of +1.00, utilize the D lens design for both eyes initially. Higher ADD powers offer fitting flexibility. Remember to prioritize prescribing the minimum necessary ADD power; avoid overprescribing. Patient feedback during trial wear is invaluable. Monitor binocular vision carefully, and be prepared to refine the ADD power based on subjective responses and objective measurements.

Lens Selection & Fitting Process
Select the distance prescription based on spherical equivalent, then choose between D or N lens designs, guided by the required ADD power for optimal vision.
Choosing Between D and N Lens Designs
Biofinity® multifocal lenses offer two distinct designs – D and N – to cater to varying ADD power needs. For ADD powers of 1.00, the recommendation is to utilize the D lens design for both the dominant and non-dominant eye. This simplifies the fitting process and often provides excellent initial results.
However, when fitting higher ADD powers, practitioners retain the flexibility to choose between D and N designs, allowing for a more customized approach to vision correction. This adaptability ensures optimal performance and patient satisfaction, enabling precise adjustments based on individual visual requirements and preferences. Careful consideration of the patient’s needs is crucial.
Fitting Lower ADD Powers
Biofinity® multifocal fitting is now remarkably simplified for lower ADD powers. When the required ADD is 1.00, a streamlined approach is recommended: utilize the D lens design for both the patient’s dominant and non-dominant eye. This consistent design choice minimizes complexity and often yields excellent initial visual acuity.
This standardized method reduces chair time and simplifies the fitting process, making it more efficient for practitioners. Remember to allow a minimum adaptation period of 15 minutes before assessing vision. This approach prioritizes ease of use without compromising on the quality of vision correction achieved with Biofinity® multifocal lenses.
Fitting Higher ADD Powers
Biofinity® multifocal lenses continue to offer flexibility when fitting higher ADD powers, allowing for personalized vision correction. Practitioners retain the option to customize lens designs for each eye – utilizing the D lens for the dominant eye and the N lens for the non-dominant eye – to optimize visual performance.
This approach enables fine-tuning based on individual patient needs and visual demands. Remember to consider a monocular over-refraction if binocular vision isn’t immediately acceptable. Careful assessment and adjustment, leveraging both D and N designs, ensures optimal distance and near vision clarity with Biofinity® multifocal lenses.

Refinement and Evaluation
Biofinity® multifocal adaptation requires a minimum 15-minute period. Monocular over-refraction, using trial lenses, helps pinpoint and correct any visual discrepancies.
Adaptation Period & Vision Assessment
Biofinity® multifocal lenses are designed for quick equilibration, however, a crucial step in the fitting process involves allowing patients a minimum adaptation period of 15 minutes. This timeframe enables the visual system to adjust to the unique multifocal design and provides a more accurate assessment of visual performance.
Following the adaptation period, a thorough vision assessment is essential. Begin with distance and near visual acuity testing under standardized lighting conditions. Pay close attention to binocularity; unacceptable binocular vision necessitates a monocular over-refraction to identify the eye requiring adjustment. Careful evaluation ensures optimal visual outcomes.
Monocular Over-Refraction Techniques
When binocular vision is suboptimal with Biofinity® multifocal lenses, employ monocular over-refraction to pinpoint the source of visual compromise. Utilize handheld trial lenses to refine the refraction in each eye independently. This technique isolates any refractive error impacting clarity.
To enhance distance vision, incrementally adjust the refractive power by -0.25D steps (up to -0.50D) in the eye needing improvement. Conversely, for near vision difficulties, apply +0.25D increments (again, up to +0.50D). This precise approach optimizes vision for each eye individually, leading to balanced binocularity.
Adjusting Distance Vision
If a patient reports unsatisfactory distance acuity with Biofinity® multifocal lenses, initiate adjustments cautiously. During monocular over-refraction, address the eye exhibiting the deficiency. To improve distance clarity, incrementally add minus power – starting with -0.25D, progressing up to -0.50D – in that specific eye.
Remember the clinical tip: prioritize maximizing plus power for distance vision and avoid over-minusing. Small adjustments can yield significant improvements. Re-evaluate binocular vision after each modification to ensure balanced and comfortable sight at all distances. Careful refinement is key to optimal outcomes.
Adjusting Near Vision
When patients experience suboptimal near vision with Biofinity® multifocal lenses, employ a similar methodical approach as with distance adjustments. Through monocular over-refraction, identify the eye requiring enhancement for near tasks. To sharpen near acuity, incrementally add minus power – beginning with -0.25D, up to a maximum of -0.50D – to the identified eye.
Remember to test near function using familiar devices like mobile phones, mirroring real-world usage. Prioritize selecting the lower ADD power whenever feasible, avoiding unnecessary over-prescription. Reassess binocular vision after each adjustment for balanced and comfortable near sight.

Clinical Considerations
Biofinity® multifocal fitting benefits from maximizing plus power for distance and evaluating near function with mobile devices; avoid over-minusing and optimize ADD power.
Maximizing Plus Power for Distance
Biofinity® multifocal lens fitting emphasizes prescribing the maximum plus power achievable for optimal distance vision. This approach aims to reduce complaints related to blurry distance acuity, a common concern with multifocal designs. Avoiding over-minus correction is crucial, as it can compromise distance clarity.
Carefully refine the distance prescription during the refraction process, ensuring the patient achieves 20/20 vision or better. Remember that a slightly plus-biased correction often yields better overall visual performance, particularly in dynamic viewing situations. Prioritizing distance clarity sets a strong foundation for successful adaptation and patient satisfaction with Biofinity® multifocal lenses.
Testing Near Function with Mobile Devices
Evaluating a patient’s near vision with their own mobile devices – smartphones or tablets – provides a realistic assessment of everyday visual performance with Biofinity® multifocal lenses. This simulates typical near tasks, revealing how the lenses function in real-world conditions.
Ask patients to perform common activities like texting, browsing the internet, or reading emails. Observe their head posture and any reported difficulties. This practical assessment complements traditional near acuity charts, offering valuable insights into the lens’s effectiveness for near tasks. It ensures the ADD power is appropriately tailored to the patient’s lifestyle.
ADD Power Optimization
When fitting Biofinity® multifocal lenses, prioritize selecting the lowest possible ADD power that provides comfortable and clear vision. Avoid overprescribing the ADD power, as this can compromise distance acuity. Start with a lower ADD and incrementally increase it only if necessary, based on patient feedback and objective measurements.
Remember, the goal is to balance distance and near vision without sacrificing clarity in either. Careful ADD power optimization ensures optimal visual performance and patient satisfaction. Consider the patient’s visual demands and lifestyle when making adjustments.
Visual Acuity Testing in Varied Lighting
During the Biofinity® multifocal fitting process, assess visual acuity under different lighting conditions. Begin testing with standard room illumination to establish a baseline. Subsequently, evaluate near vision while simulating real-world scenarios, such as using a mobile device.
Dimming the room lights can reveal potential issues with halo or glare, which may indicate the need for adjustments to lens parameters or ADD power. This comprehensive approach ensures optimal visual performance in diverse environments, maximizing patient comfort and satisfaction with their Biofinity® multifocal lenses.

Troubleshooting Common Fitting Issues
Biofinity® multifocal fitting challenges can often be resolved with monocular over-refraction, adjusting distance or near vision by +/-0.25D increments.
Addressing Distance Vision Complaints
Biofinity® multifocal lens wearers reporting distance vision issues often benefit from a simple adjustment. Begin by performing a monocular over-refraction, utilizing handheld trial lenses to pinpoint the eye requiring improvement. To enhance distance acuity, incrementally add minus power – starting with -0.25D, and progressing up to -0.50D – to the identified eye. Remember the clinical tip: prioritize prescribing the maximum plus power for optimal distance vision, avoiding over-minusing. Thoroughly reassess binocular vision after each adjustment to ensure a balanced and clear visual experience for the patient. Careful refinement leads to successful outcomes.
Resolving Near Vision Difficulties
When Biofinity® multifocal wearers struggle with near vision, a monocular over-refraction is crucial for targeted correction. Employ handheld trial lenses to determine which eye needs adjustment. To improve near acuity, incrementally add minus power – beginning with -0.25D, up to a maximum of -0.50D – to the identified eye. Remember to assess binocular vision after each modification, ensuring a comfortable and clear near visual experience. Prioritize selecting the lower ADD power whenever possible, avoiding unnecessary overprescription. This approach maximizes patient comfort and visual performance.
Managing Binocular Vision Problems
If unacceptable binocular vision arises during Biofinity® multifocal fitting, a meticulous monocular over-refraction is essential. Utilize handheld trial lenses to pinpoint the eye requiring correction. Address imbalances by adjusting either distance or near vision, adding -0.25D (up to -0.50D) as needed. Continuously evaluate binocularity after each alteration. Prioritize a balanced prescription, avoiding excessive adjustments in a single eye. Remember, the goal is harmonious binocular function, ensuring comfortable and clear vision at all distances. Careful refinement is key to successful multifocal lens adaptation.

Lens Parameters and Availability
Biofinity® multifocal lenses offer a range of base curves and diameters, alongside diverse power options and ADD powers to suit individual patient needs.
Available Base Curves and Diameters
Biofinity® Multifocal lenses are currently available in a comprehensive range of parameters designed to accommodate a broad spectrum of patient needs. Base curves are offered in 8.4mm, 8.6mm, and 8.8mm, allowing for precise corneal alignment and optimal comfort; The diameter for all available parameters is consistently 14.2mm, ensuring a suitable fit for most corneas.
This standardized diameter, coupled with the variety of base curves, contributes to enhanced lens stability and reduced rotational movement. Practitioners can leverage these options to fine-tune the fit and maximize visual acuity for their patients, ultimately leading to improved satisfaction and wearing experience.
Power Range and ADD Power Options
Biofinity® Multifocal lenses provide a wide power range, spanning from +8.00D to -8.00D in 0.25D steps, catering to a diverse patient population. This extensive spherical power availability ensures a suitable option for many refractive error corrections. Furthermore, the lenses offer ADD powers of +0.75D, +1.00D, +1.25D, +1.50D, +1.75D, and +2;00D, providing flexibility in addressing varying presbyopic needs.
The combination of broad spherical and ADD power options allows practitioners to precisely tailor the lens to each patient’s unique visual requirements, optimizing both distance and near vision correction.

Post-Fitting Patient Education
Patients require thorough instruction on proper lens care, handling, and recommended wearing schedules for optimal comfort, vision, and ocular health with Biofinity® Multifocal lenses.
Lens Care and Handling Instructions
Emphasize the importance of washing hands thoroughly with soap and water before handling lenses to prevent contamination. Patients should be instructed on proper insertion and removal techniques, utilizing recommended solutions only.
Daily cleaning with a multipurpose solution is crucial to remove deposits and maintain lens clarity. Avoid using tap water or saliva for rinsing.
Storage in a clean lens case filled with fresh solution is essential; cases should be replaced regularly. Biofinity® lenses benefit from consistent care, ensuring comfort and optimal vision. Discourage extended wear beyond the prescribed schedule.
Wearing Schedule Recommendations
Biofinity® Multifocal lenses are designed for flexible wear, but adherence to a consistent schedule is vital for optimal comfort and vision. Initially, a daily wear schedule is recommended to allow for adaptation.
Patients should gradually increase wear time as tolerated, following the eye care professional’s guidance. Extended wear options may be considered based on individual corneal physiology and patient compliance.
Regular follow-up appointments are crucial to monitor lens fit and ocular health. Always emphasize the importance of removing lenses before sleep if not specifically prescribed for overnight wear.